Skip to content

ONVIF Focus and IR Cut Filter

Note

These features require the Datastead RTSP/RTMP/HTTP/ONVIF Source filter version 9.2.4.4 or newer.

To control the focus and the IR Cut Filter, invoke ONVIFPTZStartMove:

  • The command name (PTZType parameter) is not case-sensitive.
  • The commands marked with (*) are "activation" commands: in this case, the other parameters of the function are ignored.

Focus

The supported commands are:

  • FocusNear
  • FocusFar
  • FocusAuto (*)
  • FocusManual (*)
VideoGrabber.ONVIFPTZStartMove("Focus", true, 1, 1000);
VideoGrabber.ONVIFPTZStartMove("Focus", false, 1, 1000);
VideoGrabber.ONVIFPTZStartMove("FocusNear", true, 1, 1000);
VideoGrabber.ONVIFPTZStartMove("FocusNear", false, 1, 1000);
VideoGrabber.ONVIFPTZStartMove("FocusFar", true, 1, 1000);
VideoGrabber.ONVIFPTZStartMove("FocusFar", false, 1, 1000);
VideoGrabber.ONVIFPTZStartMove("FocusAuto", true, 0, 0);
VideoGrabber.ONVIFPTZStartMove("FocusManual", true, 0, 0);

IR Cut Filter

The supported commands are:

  • IRCutOn (*)
  • IRCutOff (*)
  • IRCutAuto (*)

E.g.:

VideoGrabber.ONVIFPTZStartMove("IRCutOn", true, 0, 0);